HAZ-DUST IV Particulate Monitor

The HAZ-DUST IV displays immediate breathing zone measurements and comprehensive graph reporting of aerosol and dust for occupational hygiene and environmental air investigations. Interchangeable sampling heads enable specific particle fractions to be targeted. An inline 37 mm cassette, located behind the sensor, may be used to collect a concurrent filter sample for gravimetric or chemical analysis.

HAZ-DUST IV Particulate Monitor
HAZ-DUST IV being used by welder
Worker wearing HAZ-DUST IV
  • Easy operation and instantaneous, continuous display of TWA, STEL, Minimum, Maximum concentration in mg/m3
  • Sensor mounts directly in the breathing zone for a personal sample
  • Interchangeable sampling heads for Inhalable, Thoracic and Respirable measurements
  • External switch to select between respirable calibration to NIOSH 0600 and 2.75 L/min flow rate (GS-3 Cyclone) or inhalable calibration to NIOSH 0500 and 2 L/min flow rate (IOM Sampler)
  • In-line 37 mm cassette (or optional 25 mm cassette using adaptor) for collecting a concurrent filter sample for gravimetric or chemical analysis
  • Small and lightweight with integral belt clip
  • Operates for over 8 hours using rechargeable NiMH battery
  • Automatic data logging
  • Easy to use DustComm Pro Software for data downloading, trend analysis and comprehensive reporting of concentration changes over time
Specifications

HAZ-DUST IV operates on the principle of near-forward light scattering of infrared radiation. As the airborne particles enter the infrared beam, they scatter the light. The amount of light received by the photodetector is directly proportional to the aerosol concentration. Unique signal processing internally compensates for noise and drift. It immediately and continuously measures the concentration of airborne dust particles and displays the result in mg/m3.

Accuracy    ±10% to filter gravimetric SAE fine test dust
Sensing Range    0.01 to 200 mg/m3
Display Resolution    0.01 mg/m3
Particle Size Range    0.1 to 100 µm
Measurement Precision    ±0.02 mg/m3
Calibration    NIOSH Method 0600 gravimetric reference - NIST-traceable SAE fine test dust
Displayed Particle Concentration    Instantaneous, TWA, STEL, Minimum, Maximum
Sample Flow Rate    1.0 to 3.3 L/min (adjustable) - externally switchable 2 L/min or 2.75 L/min
Power    Rechargeable NIMH battery
Operating Time    ≥8 hours
Charging Time    10 to 12 hours
Digital Output    RS-232
Data Storage    21,500 data points
Temperature    Operating: 0 to +50°C (32 to 122°F)
Storage:   -20 to +70°C (-4 to 158°F)
Dimensions    Case:   14 x 8.3 x 7 cm (5.5 x 3.25 x 2.75 inches)
Sensor: 4.4 x 3.8 (1.75 x 1.5 inches)
Weight    680 g
HAZ-DUST IV
Description Part Number
HAZ-DUST IV Monitor Kit, includes:

Monitor, Thoracic sampling head, in-line 37 mm cassette, zeroing filter for inhalable dust, carry case, computer cable, AC Charger 110-240 V, HAZ-DUST Media USB with instruction manual and DustComm Pro Software
(requires calibration with equipment sold separately, see accessories below)

770-4004
HAZ-DUST IV Accessories
Description Part Number  
IOM Sampling Head with 25 mm cassette 225-70A  225-70A IOM Sampling Head with 25 mm cassette 
IOM Adaptor, for mounting IOM sampling head on HAZ-DUST IV 770-4204  770-4204 IOM Adaptor, for mounting IOM sampling head on HAZ-DUST IV 
Inhalable Impactor and Adaptor 770-115A  770-115A Inhalable Impactor and Adaptor 
Thoracic Sampling Head, mounts on inlet of HAZ-DUST IV sensor 770-4107  770-4107 Thoracic Impactor, mounts on inlet of HAZ-DUST IV sensor 
Respirable Impactor, GS-3 Cyclone, mounts on HAZ-DUST IV sensor 225-103  225-103 Respirable Impactor, GS-3 Cyclone, mounts on HAZ-DUST IV sensor 
Adaptor for Respirable Impactor, required when using GS-3 Cyclone 770-313  770-313 Adaptor for Respirable Impactor, required when using GS-3 Cyclone 
Calibration Standard, for verifying span and optical sensor performance 770-140  770-140 Calibration Standard, for verifying span and optical sensor performance 
Calidaptor, adaptor for calibrating the Inhalable IOM Sampling Head 391-01  391-01 Calidaptor, adaptor for calibrating the Inhalable IOM Sampling Head 
Recommended chek-mate flowmeter, 500-5000 ml/min, for calibrating the Inhalable Sampling Head

(Other Calibrators available , see Calibration)
375-0550  375-0550 chek-mate flowmeter, 500-5000 ml/min, for calibrating the Inhalable Sampling Head 
Calibration Chamber, for calibrating and setting pump airflow when using GS-3 Cyclone 225-112  225-112 Calibration Chamber, for calibrating and setting pump airflow when using GS-3 Cyclone 
Zeroing Accessory, for use with Inhalable Impactor 770-4202A  770-4202A Zeroing Filter, for use with Inhalable Impactor 
Zeroing Accessory, for use with Thoracic Impactors 770-4102  770-4102 Zeroing Filter, for use with Thoracic Impactors 
Cleaning Kit, includes bulb, swabs and lens tissue 770-305B no image
AC Charger 110-240 V 770-319 no image
Replacement NiMH Battery Pack 770-4105  770-4105 Replacement Battery Pack for HAZ-DUST IV 
Protective Pouch 770-325 no image
DustComm Pro Software on USB Flash Drive 770-225  770-225 DustComm Pro Software on USB Flash Drive 
IOM Sampling Head with 25 mm cassette

225-70A

IOM Adaptor, for mounting IOM sampling head on HAZ-DUST IV

770-4204

Inhalable Impactor and Adaptor

770-115A

Thoracic Sampling Head, mounts on inlet of HAZ-DUST IV sensor

225-4107

Respirable Impactor, GS-3 Cyclone, mounts on HAZ-DUST IV sensor

225-103

Adaptor for Respirable Impactor, required when using GS-3 Cyclone

770-313

Calibration Standard, for verifying span and optical sensor performance

770-140

Calidaptor, adaptor for calibrating the Inhalable IOM Sampling Head

391-01

chek-mate flowmeter, 500-5000 ml/min, for calibrating the Inhalable Sampling Head

375-0550

Calibration Chamber, for calibrating and setting pump airflow when using GS-3 Cyclone

225-112

Zeroing Accessory, for use with Inhalable Impactor

770-4202A

Zeroing Accessory, for use with Thoracic Impactors

770-4102

Cleaning Kit, includes bulb, swabs and lens tissue

770-305B

AC Charger 110-240 V

770-319

Replacement NiMH Battery Pack

770-4105

Protective Pouch

770-325

DustComm Pro Software on USB Flash Drive

770-225

Documentation
Haz Dust IV Instructions   Haz-Dust IV Quick Start Guide   Instructions for Calibration Standard 770-140   Instructions for Adapted IOM Sampler for HAZ-DUST IV 770-4204

HAZ-DUST IV
Instructions

 

HAZ-DUST IV
Quick Start Guide

 

770-140
Instructions

 

770-4204
Instructions