- Air Sampling Pumps
- Calibration Equipment
- Servicing and Calibration
- Sampling Heads
- Sorbent Tubes
- Passive Samplers
- Particulate Monitors
- Filters and Cassettes
- Gas Sample Bags
- Air Sampling Kits
- Gastec Detection Tubes
- Face Level Sampling
- Surface & Skin Sampling
- Asbestos Sampling
- Bioaerosol Sampling
- Environmental Sampling
- Heat Stress Monitor
- Noise Monitoring
- Vibration Monitoring
Deployable Systems
SKC offers ambient air sampling kits for 24-hour sampling, for applications such as perimeter monitoring, evaluating dust suppression/collection/ventilation controls, spray booths, and indoor air area monitoring. Supplied in one compact portable case which is easily carried or shipped.
- Fast setup with modular components and quick-connect tubing
- Ideal for remote locations, indoor air sampling and baseline surveys:
- Pre-program automatic start/stop
- 24 hour Li-Ion battery
- Secure operation from within a heavy-duty lockable case
- Quick-change battery unit
- Low noise for indoor use
- System pump provides constant, accurate airflows
- Quick-mount bracket is easy to install
- Rain cover protects sampling head
SKC provides two systems:
- Deployable Particulate Sampler (DPS) System for PM10 or PM2.5
- Deployable Cartridge Sampler (DCS) System for polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), pesticides, and associated particulates
Flow Rate | 10 L/min | |
Run Time | >24 hours (one battery charge) | |
Power Supply | Rechargeable Li-Ion battery | |
Case Dimensions | 47 x 36 x 81 cm (18.5 x 14.1 x 6.9 inches) | |
System Weight | DPS: 5.9kg (13 lbs) DCS: 5.5 kg (12.2 lbs) |
The portable SKC Deployable Particulate Sampler (DPS) system provides cost-effective PM10 or PM2.5 sampling.
Optional DataTrac software for advanced scheduling options and record keeping.
Description | Pack Size | Part Number |
DPS System with pump includes: Leland Legacy sample pump with connection case, 100-240 V AC Charger, 2 external battery assemblies with adaptors, IMPACT sampling head, 2 filter cassettes, calibration adaptor, rain cover for sampling head, 25 disposable impaction discs, filter cassette opener, tubing with quick-connect fittings, mounting bracket, in a heavy-duty, lockable carry case (requires filters, sold separately) |
||
PM10 Kit PM2.5 Kit |
Each | 100-3901 100-3903 |
DPS System without pump includes: IMPACT sampling head, 2 filter cassettes, calibration adaptor, rain cover for sampling head, 25 disposable impaction discs, filter cassette opener, tubing with quick-connect fittings, mounting bracket, in a heavy-duty, lockable carry case (requires filters, sold separately) |
||
PM10 Kit PM2.5 Kit |
Each | 225-391 225-393 |
Description | Pack Size | Part Number | |
Quartz Filters, 47 mm, Tissuquartz, 432 um thick | 25 100 |
225-1823 225-1811 |
|
PTFE Filters, 47 mm, 2.0 µm pore size, with PMP support ring | 50 | 225-1747 | |
Replacement or Additional Impact Sampling Head, includes filter cassette, calibration adaptor and rain cover for sampling head (requires filters and impaction discs, sold separately)
PM10 |
Each | 225-390 225-392 |
|
Impaction Discs, 37 mm, pre-oiled and ready for use, disposable Limited shelf life |
25 50 |
225-395 225-395A |
|
Replacement Filter Cassette for IMPACT Sampler | Each | 225-396 | |
chek-mate Flowmeter, 5.0 to 30.0 L/min flow range, battery included | Each | 375-50300 | |
Pulsation Dampener, for use with 375-50300 | Each | 375-150 | |
Replacement Rain Cover for IMPACT Sampler | Each | 225-398 | |
Replacement Mounting Bracket for IMPACT Sampler | Each | 225-399 | |
Replacement Case for DPS Systems | Each | 225-3901 | |
Petri Dish Slide for filter transport | 100 | 225-2-01 | |
DataTrac PC Software & Interface Kit for Leland Legacy, includes software on USB flash drive and DataTrac USB Interface Adaptor Cable | Each | 877-92K |
The DCS System includes the fully programmable Leland Legacy sample pump.
Optional DataTrac software for advanced scheduling options and record keeping.
Description | Pack Size | Part Number |
DCS System includes:
Leland Legacy sample pump with connection case, 100-240 V AC Charger, 2 external battery assemblies with adaptors, DCS sampling head, calibration adaptor, rain cover for sampling head, tubing with quick-connect fittings, mounting bracket, in a heavy-duty, lockable carry case (requires cartridge, filters and media sold separately) |
Each | 100-3960 |
Description | Pack Size | Part Number | |
DCS Media Cartridge with PUF/Quartz Filter in a stainless steel cartridge | Each | 226-206 | |
DCS Media Cartridge with Filter/PUF/XAD-2/PUF in a stainless steel cartridge | Each | 226-207 | |
Replacement Support Screens for DCS Cartridges | 2 | P26033 | |
Replacement PTFE Gaskets for DCS Cartridges | 4 | P52413 | |
Replacement Calibration Tubing for DCS, Tygon 5/16 inch ID, 9/16 inch OD | 3 m (10 ft) length | 225-1349 | |
chek-mate Flowmeter, 5.0 to 30.0 L/min flow range, battery included | Each | 375-50300 | |
Pulsation Dampener, for use with 375-50300 | Each | 375-150 | |
DataTrac PC Software & Interface Kit for Leland Legacy, includes software on USB flash drive and DataTrac USB Interface Adaptor Cable | Each | 877-92K |