- Air Sampling Pumps
- Calibration Equipment
- Servicing and Calibration
- Sampling Heads
- Sorbent Tubes
- Passive Samplers
- Particulate Monitors
- Filters and Cassettes
- Gas Sample Bags
- Air Sampling Kits
- Gastec Detection Tubes
- Face Level Sampling
- Surface & Skin Sampling
- Asbestos Sampling
- Bioaerosol Sampling
- Environmental Sampling
- Heat Stress Monitor
- Noise Monitoring
- Vibration Monitoring
AIR-AIDE Particulate Monitor
The AIR-AIDE is a fixed point monitor with interchangeable size-selective impactors to survey dust levels, and is powered by a long life internal air sample pump to maintain accurate flow for particle separation. The AIR-AIDE has built-in calibration factors for fine and coarse particulate matter.
- Sample pump maintains accurate flow for particle separation
- Easy to read digital display showing instantaneous readings in mg/m3, and TWA, STEL, Minimum and Maximum
- Interchangeable size-selective impactors
- Built-in correction factors for fine and coarse particulate matter
- On-screen programmable sampling and storage options
- Large data storage capacity
- 10 hour run time with rechargeable NiMH battery
- Extended running time with AC adaptor
- Optional wireless data transmission to PC
- Easy to use DustComm Pro Software for data downloading, trend analysis and comprehensive reporting of concentration changes over time
For exposure monitoring of dusts and aerosols including:
Lead | Toxic soil remediation | Silica | ||
Welding fumes | Tobacco smoke | Construction dust | ||
Coal Dust | Dry chemical | Wood/paper | ||
Oil mists | Concrete/cement | Grinding dusts | ||
Cadmium | Pharmaceuticals | Nuisance dusts | ||
Spray paint | Chromate | Grain |
Specifications
Accuracy | ±10% to filter gravimetric SAE fine test dust | |
Sensing Range | 0.001 to 20 mg/m3 (or optional 0.01 to 200 mg/m3) | |
Display Resolution | 0.001 mg/m3 | |
Particle Size Range | 0.01 to 100 µm | |
Particle Size Measurement | 1 µm, 2.5 µm, 4.0 µm or 10 µm | |
Measurement Precision | ±0.03 mg/m3 (3 µg/m3) | |
Calibration | NIOSH 0600 gravimetric reference - NIST traceable SAE fine test dust | |
Displayed Particle Concentration | Instantaneous, TWA, STEL, Minimum, Maximum | |
Sample Flow Rate | 2 L/min | |
Power | Rechargeable NiMH battery or AC adaptor | |
Operating Time | ≥10 hours | |
Charging Time | <10 hours | |
Alarm Output | 90 dB at 3 ft | |
Digital Output | RS-232 | |
Data Storage | 21,600 data points | |
Sampling Rate | Short term: 2, 4, 10 seconds, Long term: 1, 10 or 30 minutes | |
Temperature | Operating: -10 to +50°C (14 to 122°F) Storage: -20 to +70°C (-4 to 158°F) |
|
Dimensions | 7.6 x 15.2 x 22.9 cm (3 x 6 x 9") | |
Weight | 2300 g (5lbs) |
AIR-AIDE
Description | Part Number |
AIR-AIDE Kit includes,
Monitor (0.001 to 20 mg/m3), NiMH battery, 110-240 V AC charger/adaptor, rotameter, impactor sleeve for TSP, DustComm Pro Software on USB Memory Stick, RS-232 computer cable and manual |
770-600 |
AIR-AIDE Accessories
Description | Part Number | |
Size-selective Impactor PM1.0, interchangeable | 770-604 | |
Size-selective Impactor PM2.5, interchangeable | 770-605 | |
Size-selective Impactor PM4.0/respirable, interchangeable | 770-603 | |
Size-selective Impactor PM10, interchangeable | 770-606 | |
Impactor Grease | 770-211 | |
Impactor Sleeve, holds impactor for insertion into the sampling inlet | 770-602 | |
Calibration Standard, for verifying span and optical sensor performance | 770-207 | |
Radio Modem, 900 MHz with up to 450 m line-of-sight transmission | 770-505X | |
Tripod, adjustable stand (1 to 1.5 m) and mounting plate for unattended monitoring | 770-607 | |
Precipitation Cap, prevents rain and mist directly entering the sensor | 770-216 | |
Cleaning Kit, includes bulb, swabs and lens tissue (no air canister) | 770-305B | |
AC Charger 110-240 V , can be used to operate AIR-AIDE continuously | 770-608 | |
Replacement NiMH Battery Pack | 770-601 | |
DustComm Pro Software on USB Flash Drive | 770-225 |