UMEx 400 Passive Sampler for Aliphatic Amines
The SKC UMEx 400 Passive Sampler collects amines in the 0.5 to 10 ppm range. The UMEx 400 Passive Sampler contains a tape treated with 1-Naphthyl-isothiocyanate (NITC). Each sampler incorporates a “blank/ correction” section in addition to the active sampling section. Analysis is by high-performance liquid chromatography with UV detection (HPLC-UV) for identification of amines that may be present in the sample.
Sampling with the UMEx 400 Sampler is very easy and requires no pump or training. Simply remove the badge from the pouch, record sampling information on the back of the sampler, and slide the cover to the “on” position. Clip the sampler on a worker for personal sampling or in an appropriate location for area sampling for up to 8 hours. When sampling is complete, simply slide the cover to the “off” position, place the sampler back in the pouch, and seal. Send the sampler to an accredited laboratory for analysis by high-performance liquid chromatography with UV detection (HPLC-UV). The UMEx 400 sampler is designed for single use only. Do not reuse UMEx samplers.
- Same chemistry as active OSHA Method 60
- Accurate and reliable
- Validated sampling rates for:
• Methylamine
• Allyl amine
• Dimethylamine
• n-Butyl amine
• Isopropylamine
- Economical and easy to use
- No pump or training required
- Highly sensitive and specific analysis method
- Small and unobtrusive
- Simple-to-use “on/off” sliding cover
- Safe - No glass or chemical liquids in the sampler
- Concentration range from 0.5 to 10 ppm
- Use for personal or area sampling
Sampling Rate | See Sampling Rates table below | |
Detection Principle | Formation of a stable amine derivative, made from a reaction of the amine with NITC | |
Concentration Range | 0.5 to 10 ppm | |
Shelf-life | 12 months from date of manufacture in refrigerator | |
Capacity | 29 µg/sample | |
Analysis | Analysis by HPLC with UV detection at 254 nm | |
Accuracy | ± 25% for all amines except methylamine ± 35% for methylamine |
|
Storage | Before use: < 4°C (39.2°F) After use: Samples can store at ambient temperatures for 14 days. For storage greater than 14 days, store at < 4°C (39.2°F). Do not store with food. |
|
Temperature Effects | No effect on sampling rate between 10 and 30°C (50 and 86°F) | |
Wind Effects | No effect from 5 to 100 cm/s | |
Interferences | None found; highly specific for amines | |
Dimensions | 8.6 x 2.8 x 0.89 cm (3.4 x 1.1 x 0.35 inches) | |
Weight | 10.8 g (0.38 oz) |
Compound | Sampling Rate (ml/min) | |
Methylamine | 18.4 | |
Dimethylamine | 18.2 | |
Isopropylamine | 13.9 | |
Allyl amine | 22.4 | |
n-Butylamine | 18.1 |
Description | Pack Size | Part Number |
UMEx 400 Passive Sampler for Aliphatic Amines Designed for single use only. DO NOT reuse UMEx samplers. |
10 | 500-400 |