- Air Sampling Pumps
- Calibration Equipment
- Servicing and Calibration
- Sampling Heads
- Sorbent Tubes
- Passive Samplers
- Particulate Monitors
- Filters and Cassettes
- Gas Sample Bags
- Air Sampling Kits
- Gastec Detection Tubes
- Face Level Sampling
- Surface & Skin Sampling
- Asbestos Sampling
- Bioaerosol Sampling
- Environmental Sampling
- Heat Stress Monitor
- Noise Monitoring
- Vibration Monitoring
Specific Sorbent Tubes
A range of sorbent tubes utilising a variety of sorbent material.
To select a tube for a specific compound refer to the SKC Sampling Guides or use our SKC online Hazard Database
Sorbent (coating) |
Size (mm) ODxLength |
Sections | Sorbent (mg) |
Ends | Tube Cover |
Separators | Pack Size |
Part Number |
Carbon Beads (potassium hydroxide) /PTFE Filter |
16 to 8 x 85 |
2 | 100/50 | GO | H | WWWTT | 5 | 226-142 * |
Table Notes:
* Limited shelf-life; contact SKC for more information.
Tube Ends:
GS: Glass Sealed
GO: Glass Open
SS: Stainless Steel Open
Separators:
W: Glass Wool
G: Glass Fibre Filter
F: Foam
N: Nylon Ring
Q: Quartz Filter
R: Glass Spacer
S: Screen
T: PTFE Ring
Protective Tube Covers:
H: Specifically for use with 226-142 and 226-177 sorbent tubes
Only recommended for use when following methods where a Drying Tube is specifically referenced, such as NIOSH 1600 and NIOSH 2520.
Sorbent (coating) |
Size (mm) ODxLength |
Sections | Sorbent (mg) |
Ends | Tube Cover |
Separators | Pack Size |
Part Number |
Drying Tube | 10 x 160 | 1 | 900 | GS | - | WW | 50 | 226-44-02 |
Drying Tube | 6 x 70 | 1 | 250 | GS | - | WW | 50 | 226-44 |
Tube Ends:
GS: Glass Sealed
GO: Glass Open
SS: Stainless Steel Open
Separators:
W: Glass Wool
G: Glass Fibre Filter
F: Foam
N: Nylon Ring
Q: Quartz Filter
R: Glass Spacer
S: Screen
T: PTFE Ring
Sorbent (coating) |
Size (mm) ODxLength |
Sections | Sorbent (mg) |
Ends | Tube Cover |
Separators | Pack Size |
Part Number |
Firebrick (Gas chrom-R) (sulphuric acid) |
7 x 70 | 1 | 300 | GS | B | WW | 50 | 226-42-02 |
Table Notes:
* Limited shelf-life; contact SKC for more information.
Tube Ends:
GS: Glass Sealed
GO: Glass Open
SS: Stainless Steel Open
Protective Tube Covers:
A: 6 mm OD x 70 mm length
B: 8 mm OD x 110 mm length
C: 10 mm OD x 150 mm length
D: 10 mm OD x 220 mm length and shorter tubes
P: Low-volume PUF Tube Holder - Do not use an adjustable low flow holder
V: OVS Tube Holder - Do not use an adjustable low flow holder
Separators:
W: Glass Wool
G: Glass Fibre Filter
F: Foam
N: Nylon Ring
Q: Quartz Filter
R: Glass Spacer
S: Screen
T: PTFE Ring
Sorbent (coating) |
Size (mm) ODxLength |
Sections | Sorbent (mg) |
Ends | Tube Cover |
Separators | Pack Size |
Part Number |
Florisil | 6 x 70 | 2 | 100/50 | GS | A | WWW | 50 | 226-39 |
Florisil | 8 x 110 | 2 | 400/200 | GS | B | WWW | 50 | 226-39-02 |
Tube Ends:
GS: Glass Sealed
GO: Glass Open
SS: Stainless Steel Open
Protective Tube Covers:
A: 6 mm OD x 70 mm length
B: 8 mm OD x 110 mm length
C: 10 mm OD x 150 mm length
D: 10 mm OD x 220 mm length and shorter tubes
P: Low-volume PUF Tube Holder - Do not use an adjustable low flow holder
V: OVS Tube Holder - Do not use an adjustable low flow holder
Separators:
W: Glass Wool
G: Glass Fibre Filter
F: Foam
N: Nylon Ring
Q: Quartz Filter
R: Glass Spacer
S: Screen
T: PTFE Ring
Sorbent (coating) |
Size (mm) ODxLength |
Sections | Sorbent (mg) |
Ends | Tube Cover |
Separators | Pack Size |
Part Number |
Molecular Sieve (triethanolamine) | 7 x 110 | 2 | 400/200 | GS | B | WWW | 50 | 226-40-02 |
Molecular Sieve (triethanolamine) (1 tube) Oxidizer (1 tube) Molecular Sieve (triethanolamine) (1 tube) (3 tubes total) |
7 x 70 7 x 110 7 x 70 |
1 1 1 |
400 400 600 |
GS GS GS |
D | WW WW WW |
10 Sets | 226-40A |
Molecular sieve (triethanolamine) /oxidizer /molecular sieve (triethanolamine) |
10 x 110 | 3 | 400 /400 /600 |
GS | C | WWWW | 10 50 |
226-182A 226-182 |
Table Notes:
* Limited shelf-life; contact SKC for more information
† Limited shelf-life; refrigerator/freezer storage may be required. Contact SKC for more information.
Tube Ends:
GS: Glass Sealed
GO: Glass Open
SS: Stainless Steel Open
Protective Tube Covers:
A: 6 mm OD x 70 mm length
B: 8 mm OD x 110 mm length
C: 10 mm OD x 150 mm length
D: 10 mm OD x 220 mm length and shorter tubes
P: Low-volume PUF Tube Holder - Do not use an adjustable low flow holder
V: OVS Tube Holder - Do not use an adjustable low flow holder
Separators:
W: Glass Wool
G: Glass Fibre Filter
F: Foam
N: Nylon Ring
Q: Quartz Filter
R: Glass Spacer
S: Screen
T: PTFE Ring
Sorbent (coating) |
Size (mm) ODxLength |
Sections | Sorbent (mg) |
Ends | Tube Cover |
Separators | Pack Size |
Part Number |
Oxidiser Note: Currently unavailable |
7 x 110 | 1 | 800 | GS | B | WW | 20 | 226-186 |
Tube Ends:
GS: Glass Sealed
GO: Glass Open
SS: Stainless Steel Open
Protective Tube Covers:
A: 6 mm OD x 70 mm length
B: 8 mm OD x 110 mm length
C: 10 mm OD x 150 mm length
D: 10 mm OD x 220 mm length and shorter tubes
P: Low-volume PUF Tube Holder - Do not use an adjustable low flow holder
V: OVS Tube Holder - Do not use an adjustable low flow holder
Separators:
W: Glass Wool
G: Glass Fibre Filter
F: Foam
N: Nylon Ring
Q: Quartz Filter
R: Glass Spacer
S: Screen
T: PTFE Ring
Sorbent (coating) |
Size (mm) ODxLength |
Sections | Sorbent (mg) |
Ends | Tube Cover |
Separators | Pack Size |
Part Number |
Soda Lime | 7 x 110 | 2 | 600/200 | GS | B | WWWW | 50 | 226-210 |
Tube Ends:
GS: Glass Sealed
GO: Glass Open
SS: Stainless Steel Open
Protective Tube Covers:
A: 6 mm OD x 70 mm length
B: 8 mm OD x 110 mm length
C: 10 mm OD x 150 mm length
D: 10 mm OD x 220 mm length and shorter tubes
P: Low-volume PUF Tube Holder - Do not use an adjustable low flow holder
V: OVS Tube Holder - Do not use an adjustable low flow holder
Separators:
W: Glass Wool
G: Glass Fibre Filter
F: Foam
N: Nylon Ring
Q: Quartz Filter
R: Glass Spacer
S: Screen
T: PTFE Ring
These are specified by the US EPA Method 0031 in SW-846 for sampling VOCs in gaseous effluent from stationary emission sources such as hazardous waste incinerators. SKC VOST traps meet method specifications, are tested for background and pressure drop, and feature Swagelok fittings and PTFE ferrules.
Note: Traps are not supplied thermally conditioned. They must be conditioned prior to use, and used and analysed within 14 days of conditioning.
Application | Sorbent (coating) | Size (mm) ODxLength |
Ends | Pack Size |
Part Number |
EPA 0031 | Tenax TA 35/60 mesh (1.6) | 16 x 125 | GO | Each | 226-134 |
Table Notes:
* Limited shelf-life; contact SKC for more information.
Tube Ends:
GS: Glass Sealed
GO: Glass Open
SS: Stainless Steel Open