Skip to main content

VersaTrap Spore Trap Cassette

The VersaTrap spore trap cassettes provide the sampling versatility to capture mould spores and other particles ranging from 1.5 to 3.9 µm. Sampling is as easy as selecting the flow rate that will target the desired particle size (see table below), calibrating a pump to the flow rate, and collecting the sample. The narrow slit inlet focuses particles toward the clear glass slide, coated with a sticky substrate that holds the sample securely. Targeted size particles are effectively held in a well-defined rectangular footprint. VersaTrap ensures sample integrity because each slide is encased in a SureSeal certified leak-free cassette.

  • High collection efficiency
    • Captures Aspergillus and Penicillium mould spores as small as 1.5 µm at 30 L/min
  • A standard collection method for mould spore count and genus identification
  • Easy analysis - ASTM D7391-09
    • Positioning notches and flat edges provide easy alignment on microscopic stage
    • Uniform, well-defined rectangular deposition
  • Optimised slide adhesive
    • Optically clear and tested for superior adherence
  • SureSeal certified leak-free cassettes for sample integrity
  • Unique serial number on each cassette for sample traceability

Applications

  • Indoor air quality investigations
  • Cleanroom contaminant profiling
  • Infection control
  • HVAC evaluation
  • Allergy testing
  • Asbestos
  • Water intrusion
  • Fibre analysis
  • Specifications

    Sample Time    1, 2, 5, or 10 minutes
    Sampling Rate    15 L/min optimum (see table below)
    Flow Rate (L/min) VersaTrap 50% Cut-point (µm)
    30.0 1.5
    25.0 1.7
    20.0 1.9
    15.0 2.3
    10.0 2.8
    5.0 3.9
  • VersaTrap Spore Trap Cassettes

    Description Pack Size Part Number
    VersaTrap Spore Cassette, 37 mm.
    Limited shelf life
    10
    50
    225-9820
    225-9821
  • Accessories

    Description Pack Size Part Number  
    Tygon Tubing, 1/2" ID, 5/8" OD, fits over outlet of VersaTrap Spore Cassette for use with sample pumps 3 m 225-1353  225-1353 Tygon Tubing, Id 1/2 inch, length 3m, fits over outlet of VersaTrap Spore Cassette for use with sample pumps 
    Cassette Opener, stainless steel, suitable for 25, 37, and 47-mm filter cassettes.
    Required for all SureSeal Cassettes.
    Each 225-13-5B  225-13-5B SureSeal Cassette Opener, for opening 25 or 37 mm cassettes 
    Tygon Tubing, 1/2" ID, 5/8" OD, fits over outlet of VersaTrap Spore Cassette for use with sample pumps

    225-1353

    SureSeal Cassette Opener, in stainless steel for opening 25 and 37 mm cassettes. Required for all SureSeal Cassettes

    225-13-5B

  • Documentation

Read more …VersaTrap Spore Trap Cassette

Sterile Surface Swab Kit

The Surface Swab Kit is ideal for determining the relative degree and type of biological contamination in an area. This non-destructive method can be used safely on most surfaces and is ideal for irregular surfaces such as air return grills. Rayon tip is inert, non-toxic, and permits good sample retrieval and adsorption.

  • Samples surfaces for bioaerosol contamination
  • Easy and fast to use
  • Individually packed sterile swabs assure sample integrity
  • Inexpensive method
  • Suitable for characterising source contamination
  • Non-destructive

Applications include testing the level of microbial contamination on surfaces such as air conditioning units, kitchen equipment, hospital wards, spas, or areas of flooding where sewage contamination is suspected.

Easy Four Step Sampling:

  1. Remove the sterile swab from its package aseptically.
  2. Remove the sealing cap from the tube containing the sponge and moisten the swab tip.
  3. Using a rolling motion, gently swab the desired area thoroughly. Templates are included in the kit for defined area sampling.
  4. Insert the swab into the tube, replace the sealing cap, and prepare for transport to a laboratory.
  • Sterile Surface Swab Kit

    Description Pack Size Part Number
    Surface Swab Kit, contains 10 sterile swabs in transport tubes and 10 plastic templates

    Note: Limited Shelf life
    Each 225-2402
    Surface Swabs only

    Note: Limited Shelf life
    50 225-2400
  • Documentation

    Surface Swab Kit Instructions    Step by Step Surface and Skin Brochure

    Sterile Surface Swab Kit
    Instructions

      

    Step by Step -
    Surface and Skin

Read more …Sterile Surface Swab Kit

Ghost Wipes

Robust Ghost Wipes hold together even when used on the roughest surfaces. In the lab, Ghost Wipes readily and completely dissolve during digestion for maximum recovery of target analyte(s) - there is no messy fibrous material to clog the sample uptake capillary or nebuliser. Ghost Wipes are included in the Wipe Sample Test Kit (part number 225-2401A).

The methods listed below contain the full details of how to use and analyse the Ghost Wipes.

  • Robust for wiping even rough surfaces
  • Readily and completely digest in hot water or acid solution
  • Meet specifications for sampling lead and other surface metals

Ghost Wipes can also be used to collect samples of the following surface metals, as specified in OSHA Method ID-125G, Addendum B:

  • Antimony
  • Cadmium
  • Chromium
  • Cobalt
  • Copper
  • Lead
  • Manganese
  • Molybdenum
  • Nickel
  • Zinc
  • Ghost Wipes

    Description Pack Size  Part Number
    Ghost Wipes, moistened with deionised water, individually sealed packets, require 10 x 10 cm template listed below: 200

    1000
    225-2414

    225-2413
    Template, Disposable manila paper, 10 x 10 cm 10

    250
    225-2415A

    225-2415
  • Documentation

    Step by Step Surface and Skin Brochure

    Step by Step -
    Surface and Skin

Read more …Ghost Wipes

Wipe Sample Test Kit

The Wipe Sample Test Kit provides the necessary supplies to sample surfaces for toxic materials that can gain entry into the body via ingestion or skin absorption.

  • Contains materials to sample metals, pesticides, amines, radionuclides, corrosives and dust (see list below)
  • Assists in evaluating hazard control effectiveness and cleaning regimes
  • All you need for OSHA wipe sample methods (except solvents, usually distilled water, isopropanol or ethylene glycol)
  • Surface Contaminants Evaluated by Wipe Sample Test Kit

    Acrylamide Chromium, Soluble Chromic + Chromous Salts Nickel Metal & Soluble Compounds (as Ni)
    Aldrin Chromium Metal & Insoluble Salts Nitric Acid
    4-Aminodiphenyl Cobalt (+ Compounds) n-Nitrosodimethylamine
    2-Aminopyridine Copper (+ Compounds) Parathion
    Ammonia Cyanides (as CN) Phosphoric Acid
    Aniline DDT Phosphorous (Red)
    Antimony (+ Compounds) Diazinon Platinum (Soluble Salts as Pt)
    Arsenic (+ Compounds) o-Dichlorobenzene Radionuclides
    Barium (Soluble Compounds) 3,3-Dichlorobenzidine Sodium Fluoroacetate
    Benzidine Dieldrin Sodium Hydroxide
    Benzoyl Peroxide Dinitrotoluene Sulphuric Acid
    Beryllium (+ Compounds) Endrin Tellurium (+ Compounds)
    Cadmium (+ Compounds) Fluoride TEPP
    Calcium Arsenate (as As) Gallium Arsenide (Ga + As) Thallium
    Calcium Hydroxide Hydrochloric Acid Tin (as Sn)
    Calcium Oxide Lead (+ Compounds) o-Toluidine
    Chlordane Lead Chromate (as Pb) Trinitrotoluene
    Chlorinated Camphene Malathion Uranium (Soluble Compounds)
    Chlordiphenyl 4,4'-Methylene bis (2-chloroaniline)(MOCA) Warfarin
  • Wipe Sample Test Kit

    Description Pack Size  Part Number
    Wipe Sample Test Kit

    Kit contains paper and glass fibre filters, sterile sample bags, latex gloves, cotton swabs, pH paper, cover slips, 25 Ghost Wipes for lead and other metals, 72 microslides, 20 sample containers, 3 dropper bottles, 1 template (10x 10 cm), marking pen, masking tape, clear tape, stainless steel forceps and a carry case. Note that solvents are not included.

    Each 225-2401A
    Ghost Wipes, moistened with deionised water, individually sealed packets, require a 10 x 10 cm template 200
    1000
    225-2414
    225-2413
    Disposable Manila Paper, Template 10 x 10 cm (3.9 x 3.9 in) 250
    10
    225-2415
    225-2415A
  • Documentation

    Wipe Sample Test Kit Instructions

    Wipe Sample Test Kit
    Instructions

Read more …Wipe Sample Test Kit

PERMEA-TEC Pads

Toxic chemicals such as pesticides, aromatic amines, and isocyanates can permeate gloves and protective clothing. Wide variations in the chemical resistance of gloves and protective clothing compositions make protective equipment selection difficult - especially if using mixtures of chemicals in the workplace. Gloves are flexed, stretched, pressured and abraded in use which can cause premature chemical breakthrough and alter reliance on ASTM laboratory breakthrough data. PERMEA-TEC pads should be used for initial evaluation of a new glove. They are worn under gloves during actual field use and show the point at which breakthrough occurs. This information enables the safety professional to select a glove that will perform optimally in terms of protection, employee acceptance, and cost effectiveness. PERMEA-TEC pads are sensitive to 3 to 5 µg for aromatic amines and isocyanates. Solvent PERMEA-TEC pads also contain a charcoal pad for GC analysis.

The PERMEA-TEC pads should be placed on thumb, middle finger and palm with the pad side facing out before donning the gloves. These locations represent areas where the highest degree of contact and abrasion occur. The pads should be checked hourly for breakthrough.

  • PERMEA-TEC Pads

    Description Pack Size Part Number
    PERMEA-TEC Pads for Aromatic Amines 20 769-3001
    PERMEA-TEC Pads for Aromatic Isocyanates 20 769-3002
    PERMEA-TEC Pads for Aliphatic Isocyanates 20 769-3003
    PERMEA-TEC Pads for Aliphatic Amines 20 769-3005
    PERMEA-TEC Pads for Acid/Base 20 769-3006
    PERMEA-TEC Pads for Phenols 20 769-3007
    PERMEA-TEC Pads for Solvents (includes charcoal pad for GC analysis) 20 769-3050
    PERMEA-TEC Pads for Nickel 20 769-3008
    PERMEA-TEC Pads for o-Phthalaldehyde 20 769-3009
  • Documentation

    PERMEA-TEC Pads for Aromatic Amines Instructions   PERMEA-TEC Pads for Aromatic Isocyanates Instructions   PERMEA-TEC Pads for Aliphatic Isocyanates Instructions   PERMEA-TEC Pads for Aliphatic Amines Instructions   PERMEA-TEC Pads for Acid/Base Instructions   PERMEA-TEC Pads for Phenols Instructions   PERMEA-TEC Pads for Solvents Instructions

    PERMEA-TEC Pads for
    Aromatic Amines Instructions

     

    PERMEA-TEC Pads for
    Aromatic Isocyanates Instructions

     

    PERMEA-TEC Pads for
    Aliphatic Isocyanates Instructions

     

    PERMEA-TEC Pads for
    Aliphatic Amines Instructions

     

    PERMEA-TEC Pads for
    Acid/Base Instructions

     

    PERMEA-TEC Pads for
    Phenols Instructions

     

    PERMEA-TEC Pads for
    Solvents Instructions

    PERMEA-TEC Pads for Nickel Instructions   PERMEA-TEC Pads for o-Phthalaldehyde Instructions   Step by Step Surface and Skin Brochure

    PERMEA-TEC Pads for
    Nickel

     

    PERMEA-TEC Pads for
    o-Phthalaldehyde Instructions

     

    Step by Step -
    Surface and Skin

Read more …PERMEA-TEC Pads