Skip to main content

Organic Vapour Passive Samplers

SKC has scientifically validated the sampling rate of the VOC Chek 575 passive samplers along with other critical sampling parameters to meet OSHA/ASTM/ANSI requirements. SKC VOC Chek 575 Passive Samplers are identified as a viable alternative to active sampling in several OSHA methods.

  • Highly accurate and reliable
    • Proven performers in the laboratory and in the field
    • Extensively tested and documented
  • Decrease sampling costs
    • Collect most compounds with one sampler for up to a full 8 hour shift eliminating multiple trips to the worksite
    • One sampler + one analysis = money saved
    • SKC sorbents have a larger surface area for higher capacities
    • Economical solvent desorption and GC analysis
  • Variety of samplers available
    • Only SKC offers a choice of sorbents to better target specific contaminants
    • Specific samplers available for styrene and methanol
    • Sampling rates for over 300 compounds
    • Proper sorbent selection means no reverse diffusion
  • Meet ASTM D6246-08 and ANSI/ISEA 104-1998 (r 2009) standards
  • So easy to use - no pump or training required

Review the Passive Sampling Guide to identify the most appropriate sampler.

  • VOC Passive Samplers

    Description Sorbent (amount) Pack Size Part Number
    Passive Sampler for Organic Vapour Charcoal (350 mg) 5

    25

    100

    500
    575-001

    575-001A

    575-001B

    575-001C
    Passive Sampler for Organic Vapour Anasorb® 747 (500 mg) 5

    25

    100

    500
    575-002

    575-002A

    575-002B

    575-002C
    Passive Sampler for Ethylene Oxide Anasorb® 747 treated with hydrobromic acid, (500 mg) 5

    25
    575-005

    575-005A
    Passive Sampler for Styrene Anasorb® 747 coated with tert-butyl catechol (500 mg) 5 575-006
    Passive Sampler for Methanol Anasorb® 747 (500 mg) 5 575-007
  • Active/Passive Method Cross Reference

    US OSHA Methods

    Compound Active Method Tube Part No. Passive Method Sampler Part No.
    Benzene OSHA 1005 226-01 OSHA 1005 575-002
    Butyl acetates OSHA 1009 226-01 OSHA 1009 575-002
    MEK/MIBK OSHA 1004 (modified) 226-81A OSHA 1004 575-002
    Styrene OSHA 89 226-73 OSHA 1014 575-006
    Toluene OSHA 111 226-81A or 226-01 OSHA 111 575-002
    Trichloroethylene/tetrachloroethylene OSHA 1001 226-01 OSHA 1001 575-002
    Trimethylbenzene OSHA 1020 226-01 OSHA 1020 575-002
    Xylenes/ethylbenzene OSHA 1002 226-01 OSHA 1002 575-002

    UK HSE Methods

    Compound Active Method Tube Part No. Passive Method Sampler Part No.
    Benzene MDHS 104 226-01 MDHS 88 575-001
    Butyl acetates MDHS 104 226-01 MDHS 88 575-001
    MEK/MIBK MDHS 104 226-01 MDHS 88 575-002
    Styrene MDHS 104 226-01 MDHS 88 575-006
    Toluene MDHS 104 226-01 MDHS 88 575-001
    Trichloroethylene/tetrachloroethylene MDHS 104 226-01 MDHS 88 575-001
    Trimethylbenzene MDHS 104 226-01 MDHS 88 575-001
    Xylenes/ethylbenzene MDHS 104 226-01 MDHS 88 575-001
  • Analysis Accessories

    Desorption Efficiency Tubes, each single-section tube contains the sorbent type and amount equal to the corresponding passive sampler

    Sampler Pack Size Desorption Efficiency Tube Part No.
    575-001 Samplers 10 575-048
    575-002 and 575-007 Samplers 10 575-049
    575-005 Samplers 10 575-051
    575-006 Samplers 10 575-052
  • Documentation

    Organic Vapour Sampler Instructions   Methanol Passive Sampler Instructions   575 VOC Selection Guide   575 VOC Passive Sampler Spec Sheet

    575-001/002/005/006
    Instructions

     

    575-007
    Instructions

     

    Passive Sampling
    Guide

     

    VOC 575 Spec Sheet

  • VOC 575 Sampler Selection Guide

    VOC 575 Sampler Selection Guide

    VOC 575 Sampler Selection Guide

Read more …Organic Vapour Passive Samplers