What is the action level?

The action level is typically one-half the permissible exposure level. When exposures reach or exceed the action level, additional requirements…

The action level is typically one-half the permissible exposure level. When exposures reach or exceed the action level, additional requirements apply, including medical surveillance, air monitoring, etc. Simply put, it is the concentration must take some action.

What is the difference between respirable and total dust sampling?

Total dust sampling, in the traditional usage, refers to all dust particles that can be effectively collected using a filter…

Total dust sampling, in the traditional usage, refers to all dust particles that can be effectively collected using a filter cassette. Respirable dust refers to those dust particles small enough in size to get through the protective mechanisms of the nose upper airways and reach the gas exchange region of the lung (see diagram below). Respirable dust is collected using a cyclone. Some chemicals have total dust standards and some have both, depending on their potential health effects. 