Skip to main content

Specific Sorbent Tubes

A range of sorbent tubes utilising a variety of sorbent material.

Specific Sorbent Tubes
Specific Sorbent Tubes

To select a tube for a specific compound refer to the SKC Sampling Guides or use our SKC online Hazard Database

Carbon Beads Sorbent Tubes
Sorbent
(coating)
Size (mm)
ODxLength
Sections Sorbent
(mg)
Ends Tube
Cover
Separators Pack
Size
Part Number
Carbon Beads
(potassium hydroxide)
/PTFE Filter
16 to
8 x 85
 2 100/50 GO H  WWWTT 5 226-142 *  

Table Notes:

*  Limited shelf-life; contact SKC for more information.

Tube Ends:

GS:  Glass Sealed
GO:  Glass Open
SS:   Stainless Steel Open

Separators:

W:  Glass Wool
G:  Glass Fibre Filter
F:   Foam
N:   Nylon Ring
Q:   Quartz Filter
R:   Glass Spacer
S:   Screen
T:   PTFE Ring

Protective Tube Covers:

H:  Specifically for use with 226-142 and 226-177 sorbent tubes

Drying Tubes

Only recommended for use when following methods where a Drying Tube is specifically referenced, such as NIOSH 1600 and NIOSH 2520.

Sorbent
(coating)
Size (mm)
ODxLength
Sections Sorbent
(mg)
Ends Tube
Cover
Separators Pack
Size
Part Number
Drying Tube 10 x 160  1 9000 GS -  WW 50 226-44-02
Drying Tube 6 x 70  1 250 GS -  WW 50 226-44

Tube Ends:

GS:  Glass Sealed
GO:  Glass Open
SS:   Stainless Steel Open

Separators:

W:  Glass Wool
G:  Glass Fibre Filter
F:   Foam
N:   Nylon Ring
Q:   Quartz Filter
R:   Glass Spacer
S:   Screen
T:   PTFE Ring

Firebrick Sorbent Tubes
Sorbent
(coating)
Size (mm)
ODxLength
Sections Sorbent
(mg)
Ends Tube
Cover
Separators Pack
Size
Part Number
Firebrick (Gas
chrom-R
) (sulphuric acid)
7 x 70  1 300 GS B    WW 50 226-42-02

Table Notes:

*  Limited shelf-life; contact SKC for more information.

Tube Ends:

GS:  Glass Sealed
GO:  Glass Open
SS:   Stainless Steel Open

Protective Tube Covers:

A:  6 mm OD x 70 mm length
B:  8 mm OD x 110 mm length
C:  10 mm OD x 150 mm length
D:  10 mm OD x 220 mm length and shorter tubes
P:   Low-volume PUF Tube Holder - Do not use an adjustable low flow holder
V:  OVS Tube Holder - Do not use an adjustable low flow holder

Separators:

W:  Glass Wool
G:  Glass Fibre Filter
F:   Foam
N:   Nylon Ring
Q:   Quartz Filter
R:   Glass Spacer
S:   Screen
T:   PTFE Ring

Florisil Sorbent Tubes
Sorbent
(coating)
Size (mm)
ODxLength
Sections Sorbent
(mg)
Ends Tube
Cover
Separators Pack
Size
Part Number
Florisil 6 x 70  2 100/50 GS A    WWW 50 226-39
Florisil 8 x 110  2 400/200 GS B    WWW 50 226-39-02

Tube Ends:

GS:  Glass Sealed
GO:  Glass Open
SS:   Stainless Steel Open

Protective Tube Covers:

A:  6 mm OD x 70 mm length
B:  8 mm OD x 110 mm length
C:  10 mm OD x 150 mm length
D:  10 mm OD x 220 mm length and shorter tubes
P:   Low-volume PUF Tube Holder - Do not use an adjustable low flow holder
V:  OVS Tube Holder - Do not use an adjustable low flow holder

Separators:

W:  Glass Wool
G:  Glass Fibre Filter
F:   Foam
N:   Nylon Ring
Q:   Quartz Filter
R:   Glass Spacer
S:   Screen
T:   PTFE Ring

Molecular Sieve Sorbent Tubes
Sorbent
(coating)
Size (mm)
ODxLength
Sections Sorbent
(mg)
Ends Tube
Cover
Separators Pack
Size
Part Number
Molecular Sieve (triethanolamine) 7 x 110  2 400/200 GS B    WWW 50 226-40-02
Molecular Sieve (triethanolamine) (1 tube)
Oxidizer
(1 tube)
Molecular Sieve (triethanolamine)
(1 tube)
(3 tubes total)
7 x 70


7 x 110

7 x 70
 1


 1

 1
400


400

600
GS


GS

GS
D  WW


 WW

 WW
10 Sets 226-40A
Molecular sieve
(triethanolamine)
/oxidizer
/molecular sieve
(triethanolamine)
10 x 110  3 400
/400
/600
GS  C    WWWW 10
50
226-182A
226-182

Table Notes:

*  Limited shelf-life; contact SKC for more information
  Limited shelf-life; refrigerator/freezer storage may be required. Contact SKC for more information.

Tube Ends:

GS:  Glass Sealed
GO:  Glass Open
SS:   Stainless Steel Open

Protective Tube Covers:

A:  6 mm OD x 70 mm length
B:  8 mm OD x 110 mm length
C:  10 mm OD x 150 mm length
D:  10 mm OD x 220 mm length and shorter tubes
P:   Low-volume PUF Tube Holder - Do not use an adjustable low flow holder
V:  OVS Tube Holder - Do not use an adjustable low flow holder

Separators:

W:  Glass Wool
G:  Glass Fibre Filter
F:   Foam
N:   Nylon Ring
Q:   Quartz Filter
R:   Glass Spacer
S:   Screen
T:   PTFE Ring

Oxidiser Sorbent Tubes
Sorbent
(coating)
Size (mm)
ODxLength
Sections Sorbent
(mg)
Ends Tube
Cover
Separators Pack
Size
Part Number
Oxidiser
Note: Currently unavailable
7 x 110  1 800 GS  B    WW 20 226-186

Tube Ends:

GS:  Glass Sealed
GO:  Glass Open
SS:   Stainless Steel Open

Protective Tube Covers:

A:  6 mm OD x 70 mm length
B:  8 mm OD x 110 mm length
C:  10 mm OD x 150 mm length
D:  10 mm OD x 220 mm length and shorter tubes
P:   Low-volume PUF Tube Holder - Do not use an adjustable low flow holder
V:  OVS Tube Holder - Do not use an adjustable low flow holder

Separators:

W:  Glass Wool
G:  Glass Fibre Filter
F:   Foam
N:   Nylon Ring
Q:   Quartz Filter
R:   Glass Spacer
S:   Screen
T:   PTFE Ring

Soda Lime Sorbent Tubes
Sorbent
(coating)
Size (mm)
ODxLength
Sections Sorbent
(mg)
Ends Tube
Cover
Separators Pack
Size
Part Number
Soda Lime 7 x 110  2 600/200 GS  B    WWWW 50 226-210

Tube Ends:

GS:  Glass Sealed
GO:  Glass Open
SS:   Stainless Steel Open

Protective Tube Covers:

A:  6 mm OD x 70 mm length
B:  8 mm OD x 110 mm length
C:  10 mm OD x 150 mm length
D:  10 mm OD x 220 mm length and shorter tubes
P:   Low-volume PUF Tube Holder - Do not use an adjustable low flow holder
V:  OVS Tube Holder - Do not use an adjustable low flow holder

Separators:

W:  Glass Wool
G:  Glass Fibre Filter
F:   Foam
N:   Nylon Ring
Q:   Quartz Filter
R:   Glass Spacer
S:   Screen
T:   PTFE Ring

Traps for Volatile Organic Sampling Trains (VOSTs)

These are specified by the US EPA Method 0031 in SW-846 for sampling VOCs in gaseous effluent from stationary emission sources such as hazardous waste incinerators. SKC VOST traps meet method specifications, are tested for background and pressure drop, and feature Swagelok fittings and PTFE ferrules.

Note: Traps are not supplied thermally conditioned. They must be conditioned prior to use, and used and analysed within 14 days of conditioning.

Application Sorbent (coating) Size (mm)
ODxLength
Ends Pack
Size
Part Number
EPA 0031 Tenax TA 35/60 mesh (1.6) 16 x 125 GO Each 226-134

Table Notes:

*  Limited shelf-life; contact SKC for more information.

Tube Ends:

GS:  Glass Sealed
GO:  Glass Open
SS:   Stainless Steel Open